| Features: | |
| Forced current sharing at parallel operation 0.98 Typical of Power Factor SC,OL,OV,OT Protections Remote Sense, ON/OFF Contro Programmable output voltage Power Failure Signal |
|
| Specifications: | |
| Parameter | Description/SPEC.: |
| Input voltage | 100 ~ 240 VAC |
| Input frequency | 47 ~ 63 Hz |
| Input current | 4.5 A / 230 VAC |
| Inrush current | cold start < 30A |
| DC voltage Adj. | ± 5% (typical) |
| Line regulation | < 1% |
| Load regulation | < 1% |
| Leakage current | < 3.5mA / 240 VAC |
| Setup,Rise,Hold Up Time | 500 ms, 50 ms, 12 ms |
| Over Voltage Protection | 110% ~ 135% |
| Temp. Coefficient | 0.04% / °C (0 ” ~50 ”) |
| Working temp.: | 0 ” ~ 50” @ 100%, 65” @ 50% load |
| Storage temp.: | -20 ” ~ 85 ” (10% ~ 95% RH) |
| Safety standard | UL1950,TUV EN60950 |
| EMC standard: | EN55022, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, ENV50204 |
| Dimension: | 290 x 120 x 68 mm |
| Weight/packing | 2.3 kgs / pc ; 8pcs / Ctn |
|
|||||||||
| No. | Model | Input | Output | Iomin | Iomax | Load Reg. | Power | ||
| 1. | 800S-P009 | 100~240 VAC | + 9.00VDC | .00A | 88.00A | ±1.00% | 792.000(w) | ||
| 2. | 800S-P012 | 100~240 VAC | + 12.00VDC | .00A | 66.00A | ±1.00% | 792.000(w) | ||
| 3. | 800S-P015 | 100~240 VAC | + 15.00VDC | .00A | 53.00A | ±1.00% | 795.000(w) | ||
| 4. | 800S-P018 | 100~240 VAC | + 18.00VDC | .00A | 44.40A | ±1.00% | 799.200(w) | ||
| 5. | 800S-P024 | 100~240 VAC | + 24.00VDC | .00A | 33.00A | ±1.00% | 792.000(w) | ||
| 6. | 800S-P036 | 100~240 VAC | + 36.00VDC | .00A | 22.20A | ±1.00% | 799.200(w) | ||
| 7. | 800S-P048 | 100~240 VAC | + 48.00VDC | .00A | 16.00A | ±1.00% | 768.000(w) | ||
| 8. | 800S-P060 | 100~240 VAC | + 60.00VDC | .00A | 13.00A | ±1.00% | 780.000(w) | ||