| Features: |
Universal AC input / full range Fix switching frequency at 54 KHZ
(D-60) Approvals: UL / CUL / TUV / CB / CE 100% full load burn-in
test Protections: short circuit / OLP / OVP 2 years warranty |
|
| Specifications: |
| Parameter |
Description/SPEC.: |
| Input voltage |
85 ~ 264 VAC ; 120 ~ 370 VDC |
| Input frequency |
47 ~ 440 Hz |
| Inrush current |
cold start, 30 A / 115 V, 60 A / 230 V |
| O.L.P. |
105% ~ 150% hiccup mode, auto - recovery |
| O.V.P. |
CH1: 105% ~ 135% rated output voltage |
| Setup,rise,hold up time |
300ms,50ms,80ms/230VAC |
| Withstand voltage: |
I/P-O/P: 3K VAC, IP-FG: 1.5K VAC, 1min. |
| Working temp.: |
0 ” ~ 45 ” @ 100%, -10 ” @ 80%, 60 ” @ 60% |
| Safety standard |
UL60950-1, UL 1012, TUV EN60950-1 |
| EMC standard: |
EN55022 class B, EN61000-4-2,3,4,5,6,8,11, ENV50204,
ENV61000-3-2, 3 |
| Connection |
7P / 9.5 mm pitch terminal block |
| Weight/packing: |
0.55 kg / pc ; 30 pcs / 17.5 kgs / 1 CUFT |
| Dimension |
159 x 98 x 38 mm |
|
|
| No. |
Model |
Input |
Output |
Iomin |
Iomax |
Load Reg. |
Power |
| 1. |
D-60A |
85~264VAC;120~370 VDC |
+ 5.00VDC + 12.00VDC |
.30A .20A |
6.00A 4.00A |
±2.00% ±6.00% |
60.000(w) |
| 2. |
D-60B |
85~264VAC;120~370 VDC |
+ 5.00VDC + 24.00VDC |
.30A .20A |
6.00A 2.20A |
±2.00% ±5.00% |
60.000(w) |
| Other
Informations: |
| Mechanical Drawing:(mm) |
 |
|
|
|