Features:                         
Ac Input Range Selected By Switch
Protection : OLP , OVP , OTP , ShortCKT
3 color LED loading indicator
Battery Unde / Over Voltage Polarity Protection (ESC only)
Fix Switching Frequency At 25KHz
Specifications:                     
Parameter Description/SPEC.:
 Input voltage 88 ~ 132 / 176 ~ 264 VAC selected by SW.
 Inrush current cold start, 35 A at 230 VAC
 Dc adjust range 13.5V ( 12 ~ 15V ) , 27V ( 24 ~ 30V ), 54V ( 48 ~ 56V ).
 O.L.P. 105% ~ 135% fold back current limiting, Auto recovery .
 O.V.P. 115% ~ 135% of rated output Voltage
 Setup, rise, hold up time 200ms , 100ms, 15ms at full load and 230 VAC .
 Withstand voltage I/P-O/P: 3K VAC, I/P-FG: 1.5K VAC, 1min.
 Working temp. 0°C ~ 40°C @ 100%, -10°C @ 80%, 60°C @ 60%
 Safety standard CSA1010.1 (UL3101-1, IEC1010-1, EN60101-1), CSA60950-1
 EMC standard EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4, ENV50204
 Weight/packing 1.5 kgs / pc; 8 pcs / 13.0 kgs / 1.1 CUFT
Model List: CECSA_cus
No. Model Input Output Iomin Iomax Load Reg. Power
1. ESC-240-13.5 88~132/176~264 VAC + 13.50VDC .00A 16.00A ±2.00% 216.000(w)
2. ESC-240-27 88~132/176~264 VAC + 27.00VDC .00A 8.00A ±1.00% 216.000(w)
3. ESC-240-54 88~132/176~264 VAC + 54.00VDC .00A 4.00A ±1.00% 216.000(w)
4. ESP-240-13.5 88~132/176~264 VAC + 13.50VDC .00A 16.00A ±2.00% 216.000(w)
5. ESP-240-27 88~132/176~264 VAC + 27.00VDC .00A 8.00A ±1.00% 216.000(w)
6. ESP-240-54 88~132/176~264 VAC + 54.00VDC .00A 4.00A ±1.00% 216.000(w)
Other Informations: