Features:                           
High reliability
Built in EMI filter
100% full load burn-in test
OLP/OVP/Short circuit protection
1 year warranty
Specifications:                        TOP
Parameter Description/SPEC.:
 DC Input Voltage 24 (18~36)VDC
  48(36~72)VDC
  110(72~144)VDC
 Line Regulation 0.5% max
 load Regulation 0.5% max
 Output Voltage adjust range single: 10%, multi:5%
 Output Overload Protection 50W: 110~150%
  100W,300W,500W: 110~130%
 Withstand voltage I/P-O/P:1.5KV, I/P-FG:1.5KV, O/P-F/G:0.5KVAC,1min
 Isolation Resistance >100Mヘ@ 500 VDC
 Operating Temperature -10°C to +50°C
 Safety standard design refer to LVD
 EMC Standard desing refer to EN55022 , EN61000-4
 Cooling method Convection
Model List: TOP
No. Model Input Output Iomin Iomax Load Reg. Power
1. FHD300-32 36~72 VDC + 12.00VDC .00A 25.00A ±.50% 300.000(w)
2. FHD300-33 36~72 VDC + 15.00VDC .00A 20.00A ±.50% 300.000(w)
3. FHD300-39 36~72 VDC + 24.00VDC .00A 12.50A ±.50% 300.000(w)
4. FHD300-39C 36~72 VDC + 28.00VDC .00A 11.00A ±.50% 300.000(w)
5. FHD300-8A2 72~144 VDC + 12.00VDC .00A 25.00A ±.50% 300.000(w)
6. FHD300-8A3 72~144 VDC + 15.00VDC .00A 20.00A ±.50% 300.000(w)
7. FHD300-8A9 72~144 VDC + 24.00VDC .00A 12.50A ±.50% 300.000(w)
8. FHD300-8A9C 72~144 VDC + 28.00VDC .00A 11.00A ±.50% 300.000(w)