| Features: | |
| High reliability Built in EMI filter 100% full load burn-in test |
OLP/OVP/Short circuit protection 1 year warranty |
| Specifications: TOP | |
| Parameter | Description/SPEC.: |
| DC Input Voltage | 24 (18~36)VDC |
| 48(36~72)VDC | |
| 110(72~144)VDC | |
| Line Regulation | 0.5% max |
| load Regulation | 0.5% max |
| Output Voltage adjust range | single: 10%, multi:5% |
| Output Overload Protection | 50W: 110~150% |
| 100W,300W,500W: 110~130% | |
| Withstand voltage | I/P-O/P:1.5KV, I/P-FG:1.5KV, O/P-F/G:0.5KVAC,1min |
| Isolation Resistance | >100Mヘ@ 500 VDC |
| Operating Temperature | -10°C to +50°C |
| Safety standard | design refer to LVD |
| EMC Standard | desing refer to EN55022 , EN61000-4 |
| Cooling method | Convection |
|
|||||||||
| No. | Model | Input | Output | Iomin | Iomax | Load Reg. | Power | ||
| 1. | FHD500-32 | 36~72 VDC | + 12.00VDC | .00A | 42.00A | ±.50% | 500.000(w) | ||
| 2. | FHD500-32B | 36~72 VDC | + 13.80VDC | .00A | 35.00A | ±.50% | 500.000(w) | ||
| 3. | FHD500-39 | 36~72 VDC | + 24.00VDC | .00A | 21.00A | ±.50% | 500.000(w) | ||
| 4. | FHD500-8A2 | 72~144 VDC | + 12.00VDC | .00A | 42.00A | ±.50% | 500.000(w) | ||
| 5. | FHD500-8A2B | 72~144 VDC | + 13.80VDC | .00A | 35.00A | ±.50% | 500.000(w) | ||
| 6. | FHD500-8A9 | 72~144 VDC | + 24.00VDC | .00A | 21.00A | ±.50% | 500.000(w) | ||