Features:                           
AC input range selected by switch
Approvals:UL/CUL/TUV/CB/CE
UL508 listed approved
Free air cooling convection
Installed on DIN Rail TS35 / 7.5 or 15
LED indicator for power on
100% full load burn-in test
3 years warranty
120Watt Single Output Industrial DIN Rail Power Supply
Specifications:                        TOP
Parameter Description/SPEC.:
 Input Voltage 88 ~ 132 VAC ; 176 ~ 264 VDC
 Inrush Current cold start, 30 A / 115 V, 60 A / 230 V
 DC adjust range 12V: 12~14V, 24V: 24 ~ 28V, 48V: 48 ~ 53V
 O.L.P. 105% ~ 150% constant current, Auto recovery
 O.V.P. 120% ~ 140% rated output voltage
 Setup,rise, hold up time 500ms, 70ms, 30ms at full load and 230 VAC
 Withstand Voltage I/P-O/P: 3K VAC, I/P-FG: 1.5K VAC, 1min.
 Working temp. -10 ” ~ 60 ” (refer to output derating curve)
 Safety standard UL 508, TUV EN 60950-1, UL60950-1
 EMC standard EN55022, EN61000-3-2,3,
  EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2
 Connection I/P: 3 poles , O/P: 4 poles screw DIN terminal
 Weight/packing 0.79 kg; 20 pcs / 16.5 kgs / 1.1 CUFT
Notices:                           TOP
Model List: CBCETUV_serUL1_cusTOP
No. Model Input Output Iomin Iomax Load Reg. Power
1. DR-120-12 88~132VAC;176~264 VAC + 12.00VDC .00A 10.00A ±2.00% 120.000(w)
2. DR-120-24 88~132VAC;176~264 VAC + 24.00VDC .00A 5.00A ±1.00% 120.000(w)
3. DR-120-48 88~132VAC;176~264 VAC + 48.00VDC .00A 2.50A ±1.00% 120.000(w)
Remark:                           TOP
Other Informations:                      TOP
MECHANISM
MECHANISM